Search results for "Pulsed radiofrequency"
showing 9 items of 9 documents
Conventional radiofrequency treatment in five patients with trigeminal neuralgia
2010
Introduction: In trigeminal neuralgia, when drug treatment proves ineffective, other management options must be considered. In this context, conventional radiofrequency of Gasser’s ganglion is a safe and effective alternative. Material and Methods: We describe 5 patients with long-evolving trigeminal neuralgia subjected to conventional radiofrequency according to the Sweet technique, with a follow-up of two years. Results: Pain relief was complete after two months in all cases. One patient suffered an unexpected episode of nausea, vomiting and foul odor sensation that subsided after three days of rest and drug treatment. Three patients described non-painful hypoesthesia in the region of the…
Pulsed radiofrequency energy device (PEAK plasmablade™) and CustomBone® Cranioplasty: an appealing surgical rendez-vous
2019
Background: CustomBone® prosthesis is a widely recognized effective and successful technique for the reconstruction of cranial bone defects. Prior the cranioplasty implant, meticulous dissection wi...
Interventional treatment for neuropathic pain due to combined cervical radiculopathy and carpal tunnel syndrome: a case report
2017
Key Clinical Message The coexistence of median and cervical nerve root damage might hide a complex pathophysiology. Here, we describe and discuss the case of a patient suffering from numbness and painful tingling of the hand, whose symptoms were effectively treated with pulsed radiofrequency and epidural administration of bupivacaine and morphine.
Human sleep under the influence of pulsed radiofrequency electromagnetic fields: A polysomnographic study using standardized conditions
1998
To investigate the influence of radiofrequency electromagnetic fields (EMFs) of cellular phone GSM signals on human sleep electroencephalographic (EEG) pattern, all-night polysomnographies of 24 healthy male subjects were recorded, both with and without exposure to a circular polarized EMF (900 MHz, pulsed with a frequency of 217 Hz, pulse width 577 μs, power flux density 0.2 W/m2. Suppression of rapid eye movement (REM) sleep as well as a sleep-inducing effect under field exposure did not reach statistical significance, so that previous results indicating alterations of these sleep parameters could not be replicated. Spectral power analysis also did not reveal any alterations of the EEG rh…
The Influence of All-Night Exposure to Pulsed Radiofrequency Electromagnetic Fields on Human Sleep. Der Einfluss kontinuierlicher nachtlicher Exposit…
2005
Question of the study The widespread use of mobile telephones has led to public discussion about the putative health hazards as well as scientific interest in the interactions of pulsed, high-frequency electromagnetic fields with physiological systems. This article presents a survey of three consecutive studies carried out by a research group at the University of Mainz.
Electrocatheter-mediated High-voltage Pulsed Radiofrequency of the Dorsal Root Ganglion in the Treatment of Chronic Lumbosacral Neuropathic Pain
2019
Objectives:Despite the interest in scientific community, there is still poor evidence about pulsed radiofrequency (PRF) efficacy in the treatment of neuropathic pain. In order to determine whether high-voltage PRF and epidural adhesiolysis (PRF-EA) showed better results than epidural adhesiolysis al
Electrocatheter-mediated High-voltage Pulsed Radiofrequency of the Dorsal Root Ganglion in the Treatment of Chronic Lumbosacral Neuropathic Pain
2019
Objectives: Despite the interest in scientific community, there is still poor evidence about pulsed radiofrequency (PRF) efficacy in the treatment of neuropathic pain. In order to determine whether high-voltage PRF and epidural adhesiolysis (PRF-EA) showed better results than epidural adhesiolysis alone (EA), a randomized, double-blind, comparative-effectiveness study was conducted in patients with chronic lumbosacral radiating pain and neuropathic features. Materials and Methods: A total of 41 patients were randomly allocated to 2 groups. Twenty-one patients were randomized to receive 2 cycles of 240 seconds high-voltage PRF followed by the injection of local anesthetics, hyaluronidase, an…
Radiofrequency treatment of cervicogenic headache
2010
Objectives: In the clinical management of facial pain, a possible cervical origin must be considered. A clinical exploration is therefore essential. The disorder originates in the intimate connections between the cranial portion of the spinal cord and the trigeminal system. Although solid evidence supporting the use of radiofrequency (RF) treatment is lacking, it remains one of the management options to be taken into account. The present study evalu - ates the efficacy of RF in application to cervicogenic headache. Study design: We present three cases of severe facial pain arising from different cervical structures. Results: In two cases the pain originated in cervical roots C2 and C3, whil…